A solar pump is an application of photo-voltaic technology which converts solar energy in to electricity to run motor and pump.The motor powered by solar energy draws water out of borewell, river, lake or pond
The photo-voltaic cells in solar modules converts unlight in to Direct Current (DC) electrical energy. This energy is fed to the pump via Pump Controller in case of DC pump or via Variable Frequency Drive (VFD) in case of AC pumps (VFD converts DC into Alternative Current (AC)). Pump system is a combination of an impeller and a motor; the impeller propels water movement and the motor drives the pump. The water is propelled out of the borewell / river/ lake/ pond through the pipe; water can then be to the fields to thef ields for irrigation and other purposes. Water output varies during the day with varying solar irradiance.
Pump Controller | Operating Voltage DC Vtg | Modules Required Panel | Module Combination | VOC of eacH Module |
---|---|---|---|---|
1 HP 3 Ph 110V | 150-300 | 1000-1200Watt | 300WX4No. | 42-45V |
2 HP 3 Ph 160V | 200-350 | 2400Watt | 300WX8No. String of 12 Panel |
42-44V |
3 HP 3 Ph 220V | 200-700 | 3000Watt | 300WX10No. 1 String of 10 Panel |
42-44V |
5 HP 3 Ph 415V | 500-700 | 5200Watt | 320WX15/16No. 1 String of 16 Panel |
42-44V |
7.5 HP 3 Ph 415V | 500-700 | 7500Watt | 3250WX30/32No. 2 Strings of 15/16 Panel |
42-44V |
10 HP 3 Ph 415V | 500-750 | 10400Watt | 320WX32No. 2 String of 16 Panel |
42-44V |
15 HP 3 Ph 415V | 500-750 | 15600Watt | 320WX48No 3 String of 16 Panel |
42-44V |
20 HP 3 Ph 415V | 500-750 | 20800Watt | 320WX64No. 4 String of 16 Pane |
42-44V |
25 HP 3 Ph 415V | 500-750 | 225600Watt | 320WX80No. 5 String of 16 Panel |
42-44V |
Input specificationV | |
Maximum Input DC Voltage | 400VDC |
Recommended Voc Range | 320~370VDC |
Recommended MPPT Voltage Range | 250~350VDC |
Starting Voltage Range | 120~400VDC |
Grid or backup generator input | |
Input Voltage Single phase | 220V(-15%~30% |
Output specification | |
Rated output voltage | 3PH 220V |
Output frequency | 0~600.00Hz(Default 0~50.00Hz) |
Protection | |
Built-in Protection | Lighting Protection, over-current, over voltage, output phase-lose, under-load, under-voltage, short circuit, overheating, water pump run dry etc |
General Parameters | |
Application Site | No direct sunshine, no dust, corrosive gas, combustible gas, oil mist steam, dripping or salinity etc. |
Altitude | 0~2000 m Derated use above 1000m, per 100m, the rated output current decrease 1% |
Env. Temperature | -10°C~40°C (Environment temperature be 40°C~50°C, please keep derated use.) |
Humidity | 5~95%, non-condensation |
Vibration | Less than 5.9 m/s 2 (0.6g) |
Storage Temperature | -20°C~+70°C |
Efficiency | Rated power Run>93% |
Installation | Wall or rail mounting |
Cooling | Forced Air cooling |
Protection | Ip20 |
Input specificationV | |
Maximum Input DC Voltage | 800VDC |
Recommended Voc Range | 500~700VDC |
Recommended MPPT Voltage Range | 450~600VDC |
Starting Voltage Range | 250~400VDC |
Grid or backup generator input | |
Input Voltage Single phase | Three phase 380V(-15%~30%) |
Output specification | |
Rated output voltage | 3PH 380V |
Output frequency | 0~600.00Hz(Default 0~50.00Hz) |
Protection | |
Built-in Protection | Lighting Protection, over-current, overvoltage, output phase-lose, under-load, under-voltage, short circuit, overheating, water pump run dry etc |
General Parameters | |
Application Site | No direct sunshine, no dust, corrosive gas, combustible gas, oil mist steam, dripping or salinity etc. |
Altitude | 0~2000 m Derated use above 1000m, per 100m, the rated output current decrease 1% |
Env. Temperature | -10°C~40°C (Environment temperature be 40°C~50°C, please keep derated use.) |
Humidity | 5~95%, non-condensation |
Vibration | Less than 5.9 m/s 2 (0.6g) |
Storage Temperature | -20°C~+70°C |
Efficiency | Rated power Run>93% |
Installation | Wall or rail mounting |
Cooling | Forced Air cooling |
Protection | Ip20 |
*Due to continous improvements actual specifications may change without prior notice