Power Products

home-ups-tamis

Home UPS - Tamis

In todays fast pace world, where time is money it is essential to arm yourself against all the shortcomings. With frequest shutdown & blackouts in power supply it is important to have reliable & uninterrupted power supply to operate efficiently. Vitronics controls is a correct alternative that takes care of all your power needs during the power crises.

Salient Features

  • Intelligent, Microcontroller based design
  • 110 to 300 V Mains I/P, compatible to generator
  • Intelligent charging, Reduces electricity bill
  • Automatic Battery Health checkup as well as battery bad detection
  • Error code display
  • Auto reset on overload
  • Single card design, easy for servicing
  • Charging from 110 V

Features

  • DSP based; less components, small size less electricity bill more efficiency.
  • Soft Start features; protects appliances at start up.
  • Last Fault Display and record : the system records the last fault and you can analyze it.
  • Adaptive loss reduction process gives more efficient charging system.
  • 5 stag battery charge control system for lower gassing and faster Charging
  • In built SBM (Smart Battery Management) system to provide higher degree battery production & life
  • Battery usage data is recorded for better evaluation of battery.
  • Supply the highest quality pure sine wave power; protects your expensive household appliance &sensitive office equipments.
  • Musical Alarm
  • Highly cost effective design with special features to safeguard the mosfets to poor electrical quantity.
  • Over load and D.C. low protection
  • Software controlled Auto self testing
  • Fully computer friendly UPS operation.
  • Intelligent Auto sense; continuously monitors health of system.
  • AC input low & high voltage cut off protections in both, invertor & U.P.S.modes.
  • Silent operation of fans, tube light or appliances.
  • Quick Change over from Mains to inverter mode.
  • Software controlled Auto reset feature for over load, Short ckt & low battery.
  • Very low no load current for prolonged battery operation under standby.
  • Cooling fan improves reliability of system.

Technical Specifications

Model 400VA/800VA/1000VA/12V 1600VA/2500VA/24V 3500VA/5000VA/48V
Input Voltage (UPS) 180-260V 180-260V 180-260V
Input Voltage (INV) 130-280V 130-280V 130-280V
Output Voltage on mains mode Same as input Same as input Same as input
Output Frequency on inverter mode 50Hz ±0.1Hz 50Hz ±0.1Hz 50Hz ±0.1Hz
Model
A.C Output Voltage of inverter, Mains Voltage input of inverter, Mains Frequency of the inverter, Inverter Load %, Battery Current
Battery Level in %, Battery Status, Inverter Status, Inverter Error (if any), Solar Voltage, Solar Current, Solar watts, Solar KWH
Solar Voltage, Days in service, Solar Status & mode of operation
Bill reducing protocol Available Available Available
Output Waveform on mains mode Same as input Same as input Same as input
Output Waveform on inverter mode PURE SINE WAVE PURE SINE WAVE PURE SINE WAVE
Overload 110%
Overload delay 0-20sec Settable for handling motor loads
Overload restart 5 times Auto restart on over load
Charging current 5amp till 20amps
Charging process 5 stage charging process
Data logged Battery usage Number of time battery discharged till warning and number times battery charged
  Last Fault record Last Fault record
Mode control Fast/slow For computer applications select fast mode In fast mode transfer is within 4milli sec

*Due to continous improvements actual specifications may change without prior notice

Download Brochure